Abstract

A simple wavelength reference was constructed by illuminating an athermal silica-based Mach-Zehnder interferometer filter with a broadband light source. The nonlinear wavelength-voltage response of a Fabry-Perot tunable filter can be calibrated by using the constructed wavelength reference. The maximum wavelength deviation of the calibrated system with the Fabry-Perot tunable filter is 6×10-5nm over a monitoring period of 12h.
Original languageEnglish
Pages (from-to)1422-1424
Number of pages3
JournalElectronics Letters
Volume42
Issue number24
DOIs
Publication statusPublished - 6 Dec 2006