TY - GEN
T1 - Tests on strength of coped beams with web stiffening
AU - Yam, Chi Ho Michael
AU - Ma, Hongwei
AU - Chung, Kwok Fai
PY - 2011/1/19
Y1 - 2011/1/19
N2 - In steel construction, when beams have to be connected to a girder at the same elevation, beam flanges must often be coped to provide enough clearance for practical joint formation. The presence of a cope in a beam will reduce the strength of the beam in the coped region. To improve the strength of coped beams, web reinforcements at the coped region were proposed in previous research studies. This paper reports the results of the first phase of the experimental program. A total of 8 tests were conducted. The test parameters include the length of longitudinal stiffeners, cope depth to beam depth ratio, cope length to beam depth ratio, and doubler plate. The test results show that the strength of the coped beam specimens was significantly increased when stiffeners were used in the cope. The increase in strength due to the presence of the longitudinal stiffeners could be as high as 96%. The longitudinal stiffeners were able to prevent local web buckling from occurring at the cope, however, the final failure mode of the beams was yielding of non-reduced section followed by rigid body movement of stiffener. The doubler plate was able to increase the strength of the beams; however, the final failure mode of the beams was still local web buckling.
AB - In steel construction, when beams have to be connected to a girder at the same elevation, beam flanges must often be coped to provide enough clearance for practical joint formation. The presence of a cope in a beam will reduce the strength of the beam in the coped region. To improve the strength of coped beams, web reinforcements at the coped region were proposed in previous research studies. This paper reports the results of the first phase of the experimental program. A total of 8 tests were conducted. The test parameters include the length of longitudinal stiffeners, cope depth to beam depth ratio, cope length to beam depth ratio, and doubler plate. The test results show that the strength of the coped beam specimens was significantly increased when stiffeners were used in the cope. The increase in strength due to the presence of the longitudinal stiffeners could be as high as 96%. The longitudinal stiffeners were able to prevent local web buckling from occurring at the cope, however, the final failure mode of the beams was yielding of non-reduced section followed by rigid body movement of stiffener. The doubler plate was able to increase the strength of the beams; however, the final failure mode of the beams was still local web buckling.
KW - Coped beam
KW - Doubler plate
KW - Longitudinal stiffener
KW - Test
KW - Web buckling
UR - http://www.scopus.com/inward/record.url?scp=78651383044&partnerID=8YFLogxK
U2 - 10.4028/www.scientific.net/AMR.163-167.605
DO - 10.4028/www.scientific.net/AMR.163-167.605
M3 - Conference article published in proceeding or book
SN - 9780878492060
T3 - Advanced Materials Research
SP - 605
EP - 609
BT - Advances in Structures
T2 - 2011 International Conference on Structures and Building Materials, ICSBM 2011
Y2 - 7 January 2011 through 9 January 2011
ER -