Abstract

In this study, steel staggered truss frame (SSTF) with hybrid steel in the vierendeel panels is developed. In particular, the concept of a hybrid SSTF can be realised by a wise combination of steel members with various yield strengths to trigger early yielding of chords in the vierendeel panels under seismic attacks. Thus, the seismic energy is allowed to be dissipated at the special region of the SSTF (i.e. the vierendeel panels) for a wide deformation range. The seismic performance of a hybrid SSTF is studied by examining a 6-storey prototype structure. For comparison, a conventional SSTF structure without hybrid steel technology is also studied. Two 3-dimensional models of the SSTF systems are studied, and the numerical models are developed using beam elements. Based on numerical models of prototype structures verified by the test results, seismic response quantities including initial stiffness, energy dissipation, ultimate strength, and rigidity degeneration are analysed. Seismic performance of the prototype systems is evaluated using nonlinear static (pushover) analysis and incremental dynamic analyses (IDA). Pushover analysis with the invariant lateral load distribution corresponding to the first mode is adopted in this study. The pushover curves show that a hybrid SSTF exhibits a wide damage-control stage and significant post-yielding stiffness ratio. The plastic hinges are formed in the vierendeel panels and column bases. No plastic hinges are formed in the chord and the diagonal members outside the vierendeel panels. The yielding sequences make the hybrid SSTF shows multi-stage performance. Subsequently, a total of ten (10) ground motion records are used in the dynamic analysis according to the FEMA P695 recommendations. Record scaling includes two steps. In the first step, individual records in each set are “normalised” by their respective peak ground velocities (PGV). In the second step, “normalised” records are amplified to a specific seismic magnitude and used as input excitations to examine the response of the structures. It can be observed from the nonlinear dynamic analysis results that the residual displacement of the hybrid SSTF is less than the conventional SSTF structure. Nonlinear incremental dynamic analyses is used to compute the collapse margin ratio for both structures under the amplified levels of earthquake, and the results have been compared with the recommended values by the FEMA P695. The collapse margin ratio for evaluation of seismic safety of the hybrid SSTF is larger than that of the conventional SSTF structure. The conventional SSTF has higher values than the hybrid SSTF in the maximum and residual interstorey drift. In general, the observations drawn from this work show that the hybrid SSTF has more encouraging seismic performance compared with the conventional SSTF structure.

Original languageEnglish
Title of host publicationWorld Conference on Earthquake Engineering proceedings
PublisherInternational Association for Earthquake Engineering
Publication statusPublished - Sept 2021

Publication series

NameWorld Conference on Earthquake Engineering proceedings
Volume2021
ISSN (Electronic)3006-5933

Keywords

  • hybrid steel staggered truss frame
  • incremental dynamic analyses
  • pushover analysis
  • residual deformation

ASJC Scopus subject areas

  • Geophysics
  • Geotechnical Engineering and Engineering Geology
  • Civil and Structural Engineering
  • Safety, Risk, Reliability and Quality
  • Engineering (miscellaneous)
  • Building and Construction

Fingerprint

Dive into the research topics of 'SEISMIC PERFORMANCE OF HYBRID STEEL STAGGERED TRUSS FRAME'. Together they form a unique fingerprint.

Cite this