TY - GEN
T1 - Screening for a university library Indoor air quality (IAQ)
AU - Zhang, Dadi
AU - Wong, Ling Tim
AU - Mui, Kwok Wai
N1 - Publisher Copyright:
© 2024 18th Conference of the International Society of Indoor Air Quality and Climate, INDOOR AIR 2024 - Conference Program and Proceedings. All rights reserved.
PY - 2024/7
Y1 - 2024/7
N2 - Completing a full IAQ evaluation would be difficult since different indicators require different measurement devices. Therefore, a recent study proposed an IAQ index using only three indicators to identify poor IAQ in air-conditioned buildings. A similar method was applied in the present study to evaluate the IAQ in an air-conditioned university library. Both questionnaire surveys and onsite measurements were conducted in a university library for five consecutive days. The IAQ indexes were calculated based on the measured values of CO2, PM10, and TVOC; the related likelihood ratios that were used to indicate the probabilities of occupants’ dissatisfaction with the IAQ were calculated based on the questionnaire results. Results indicated that the investigated library had a lower risk of dissatisfying students: the IAQ unsatisfactory probabilities were less than 50% during the whole measurement period, and the unsatisfactory probabilities were less than 20% during 73% of the time.
AB - Completing a full IAQ evaluation would be difficult since different indicators require different measurement devices. Therefore, a recent study proposed an IAQ index using only three indicators to identify poor IAQ in air-conditioned buildings. A similar method was applied in the present study to evaluate the IAQ in an air-conditioned university library. Both questionnaire surveys and onsite measurements were conducted in a university library for five consecutive days. The IAQ indexes were calculated based on the measured values of CO2, PM10, and TVOC; the related likelihood ratios that were used to indicate the probabilities of occupants’ dissatisfaction with the IAQ were calculated based on the questionnaire results. Results indicated that the investigated library had a lower risk of dissatisfying students: the IAQ unsatisfactory probabilities were less than 50% during the whole measurement period, and the unsatisfactory probabilities were less than 20% during 73% of the time.
KW - Air-conditioned library
KW - IAQ index
KW - IAQ screening
KW - Questionnaire survey
UR - https://www.scopus.com/pages/publications/85210839808
M3 - Conference article published in proceeding or book
AN - SCOPUS:85210839808
T3 - 18th Conference of the International Society of Indoor Air Quality and Climate, INDOOR AIR 2024 - Conference Program and Proceedings
BT - 18th Conference of the International Society of Indoor Air Quality and Climate, INDOOR AIR 2024 - Conference Program and Proceedings
PB - International Society of Indoor Air Quality and Climate
T2 - 18th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2024
Y2 - 7 July 2024 through 11 July 2024
ER -