Reduction of Physiological Strain Under a Hot and Humid Environment by a Hybrid Cooling Vest

Albert P.C. Chan, Yang Yang, Francis K.W. Wong, Michael C.H. Yam, Del P. Wong, Wen Fang Song

Research output: Journal article publicationJournal articleAcademic researchpeer-review

14 Citations (Scopus)

Abstract

Chan, APC, Yang, Y, Wong, FKW, Yam, MCH, Wong, DP, and Song, W-F. Reduction of physiological strain under a hot and humid environment by a hybrid cooling vest. J Strength Cond Res 33(5): 1429-1436, 2019-Cooling treatment is regarded as one of good practices to provide safe training conditions to athletic trainers in the hot environment. The present study aimed to investigate whether wearing a commercial lightweight and portable hybrid cooling vest that combines air ventilation fans with frozen gel packs was an effective means to reduce participants' body heat strain. In this within-subject repeated measures study, 10 male volunteers participated in 2 heat-stress trials (one with the cooling vest-COOL condition, and another without-CON condition, in a randomized order) inside a climatic chamber with a controlled ambient temperature 33° C and relative humidity (RH) 75% on an experimental day. Each trial included a progressively incremental running test, followed by a 40-minute postexercise recovery. Core temperature (Tc), heart rate (HR), sweat rate (SR), rating of perceived exertion (RPE), exercise duration, running distance, and power output were measured. When comparing the 2 conditions, a nonstatistically significant moderate cooling effect in rate of increase in Tc (0.03 ± 0.02° C·min for COOL vs. 0.04 ± 0.02° C·min for CON, p = 0.054, d = 0.57), HR (3 ± 1 b·min·min for COOL vs. 4 ± 1 b·min·min for CON, p = 0.229, d = 0.40), and physiological strain index (PSI) (0.20 ± 0.06 unit·min for COOL vs. 0.23 ± 0.06 unit·min for CON, p = 0.072, d = 0.50) was found in the COOL condition during exercise. A nonstatistically significant (p > 0.05) trivial cooling effect (d < 0.2) was observed between the COOL and CON conditions for measures of exercise duration, running distance, power output, SR, and RPE. It is concluded that the use of the hybrid cooling vest achieved a moderate cooling effect in lowering the rate of increase in physiological strain without impeding the performance of progressively incremental exercise in the heat.

Original languageEnglish
Pages (from-to)1429-1436
Number of pages8
JournalJournal of Strength and Conditioning Research
Volume33
Issue number5
DOIs
Publication statusPublished - 1 May 2019

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Physical Therapy, Sports Therapy and Rehabilitation

Fingerprint

Dive into the research topics of 'Reduction of Physiological Strain Under a Hot and Humid Environment by a Hybrid Cooling Vest'. Together they form a unique fingerprint.

Cite this