Abstract
This paper presents a numerical investigation on the energy dissipative and recentering behavior of I-beam to CHS column connections equipped with NiTi shape memory alloy (SMA) and steel tendons under cyclic loads. The finite element methodology has been validated against the companion experimental investigation. Numerical results have captured successfully the experimental observations including the load-deformation history and failure mode. Based on the validated finite element methodology, parametric analysis has been conducted to investigate the influence of the initial prestress and the geometric arrangement of the SMA tendons. Results indicated that by increasing the tendons' initial prestress, the connection's initial stiffness and energy dissipative performance increase. Under the same drift level, connection equipped with shorter tendons displayed higher energy dissipation while connection with the SMA tendons located outside the beam flanges showed higher energy dissipation.
Original language | English |
---|---|
Pages (from-to) | 114-124 |
Number of pages | 11 |
Journal | Structures |
Volume | 4 |
DOIs | |
Publication status | Published - 1 Jan 2015 |
Keywords
- Cyclic load
- Energy dissipation
- Numerical simulation
- Recentering
- Shape memory alloy
- Steel connection
ASJC Scopus subject areas
- Architecture
- Civil and Structural Engineering
- Building and Construction
- Safety, Risk, Reliability and Quality