Abstract
In Part 1 of the study, two improved Bouc-Wen models have been proposed to describe the hysteretic behaviour of a wire-cable vibration isolator. In this part, a frequency-domain parametric identification procedure is presented to determine the model parameters from the experimental data of the cyclic loading test. Making use of the rate-independent nature of the hysteretic behaviour, the measured quasi-periodic data sequences are modulated to periodic signals. Then the model parameters are identified from a one-stage estimate scheme using the acquired harmonic components of the displacement and restoring force signals. The identification results give rise to a good representation of the experimental hysteresis loops. After performing the modelling, the dynamic response behaviour of a wire-cable isolation system is evaluated with reference to the shear, the roll and the tensioncompression modes respectively. The frequency-response characteristics in the tension-compression mode are found to be greatly different from those in shear and roll modes.
Original language | English |
---|---|
Pages (from-to) | 173-182 |
Number of pages | 10 |
Journal | Proceedings of the Institution of Mechanical Engineers. Part I: Journal of Systems and Control Engineering |
Volume | 213 |
Issue number | 3 |
DOIs | |
Publication status | Published - 1 Jan 1999 |
Keywords
- Dynamic response
- Parametric identification
- Wire-cable vibration isolator
ASJC Scopus subject areas
- Control and Systems Engineering
- Mechanical Engineering