Abstract
The coupled interior sound fields and its frequency response due to vibrating sources of low frequencies on the roof have been calculated by using of finite element method (FEM). The results show that there are some differences of mode frequencies between thin-walled and rigid walled of the same dimension rectangular rooms, and it is found that the difference will be larger since the mode frequency is larger. If the exciting forces frequency is near by the resonance frequency of room structure or the sound mode frequency of the room, the pressure level of coupled interior sound fields will be enhanced. When the structure resonance frequency is equal to the room's mode frequency, the sound pressure level in the room will become very high at this exciting frequency. So this case must be avoided in the engineering. The sound pressure level and the displacement on the all walls are separately calculated at the characteristic and non-characteristic frequency (80 Hz and 116 Hz). It reveals that the mostly sound energy radiated to the room is not always contributed by the roof, sometimes the other walls may be the mostly one.
Original language | Chinese (Simplified) |
---|---|
Pages (from-to) | 338-343 |
Number of pages | 6 |
Journal | Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology |
Volume | 36 |
Issue number | 3 |
Publication status | Published - 1 Mar 2004 |
Keywords
- Coupled sound fields
- Exciting forces
- Frequency response
- Structure vibration