Abstract
The growth behavior of short fatigue crack in a single crystal nickel-based superalloy SC16 is investigated using in-situ SEM fatigue testing. The configuration of in-situ SEM fatigue testing system used is discussed. The test material has nominal chemical compositions of 3.5%Al, 3.5%Ti, 3.5%Ta, 15.4%Cr, 2.8%Mo and the balance is nickel.
| Original language | English |
|---|---|
| Pages (from-to) | 2443-2448 |
| Number of pages | 6 |
| Journal | Scripta Materialia |
| Volume | 44 |
| Issue number | 10 |
| DOIs | |
| Publication status | Published - 25 May 2001 |
| Externally published | Yes |
Keywords
- In-situ SEM fatigue
- Short crack
- Single-crystal SC16
- Slip bands
ASJC Scopus subject areas
- General Materials Science
- Condensed Matter Physics
- Mechanics of Materials
- Mechanical Engineering
- Metals and Alloys