High sensitivity and stability cavity-enhanced photoacoustic spectroscopy with dual-locking scheme

Kaiyuan Zheng, Wenxuan Luo, LiFu Duan, Shuangxiang Zhao, Shoulin Jiang, Haihong Bao, Hoi Lut Ho, Chuantao Zheng, Yu Zhang, Weilin Ye (Corresponding Author), Wei Jin (Corresponding Author)

Research output: Journal article publicationJournal articleAcademic researchpeer-review

5 Citations (Scopus)

Abstract

We present a high sensitivity and long-term stability cavity-enhanced photoacoustic spectroscopy (CE-PAS) system with optical cavity and acoustic frequency dual-locking scheme for trace acetylene (C 2H 2) detection. The first mechanism involves locking the optical wavelength to the cavity resonance by comparing the phase-sensitive component of the reflected light with a reference signal in a feedback loop. The second locking mechanism controls the gas proportion inside the photoacoustic cell to lock the acoustic frequency, suppressing the drift caused by environmental temperature variation. By minimizing amplitude fluctuations through dual-locking, the sensor achieves improved stability with reduced fluctuations from ±10.12 % to ±1.16 %. The linear responsivity and excellent linearity of the sensor are demonstrated over a concentration variation spanning four orders of magnitude. Experimental results showcase a minimum detection limit of 1.2 parts-per-billion (ppb) at an integration time of 400 s, corresponding to a normalized noise equivalent absorption (NNEA) coefficient of 1.37×10 −11 cm −1·W· Hz −1/2 for C 2H 2 detection. Long-term stability is within ±2 % over a 15-day period. The combination of high sensitivity and long-term stability make this CE-PAS sensor suitable for a wide range of applications in environmental monitoring, industrial process control, and gas leak detection.

Original languageEnglish
Article number135984
JournalSensors and Actuators B: Chemical
Volume415
DOIs
Publication statusPublished - 15 Sept 2024

Keywords

  • Acoustic frequency drift
  • Cavity-enhanced spectroscopy
  • Dual-locking scheme
  • Gas sensor
  • Photoacoustic spectroscopy

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Metals and Alloys
  • Instrumentation
  • Materials Chemistry
  • Surfaces, Coatings and Films
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'High sensitivity and stability cavity-enhanced photoacoustic spectroscopy with dual-locking scheme'. Together they form a unique fingerprint.

Cite this