TY - JOUR
T1 - High formability Mg-Zn-Gd wire facilitates ACL reconstruction via its swift degradation to accelerate intra-tunnel endochondral ossification
AU - He, Xuan
AU - Li, Ye
AU - Miao, Hongwei
AU - Xu, Jiankun
AU - Ong, Michael Tim yun
AU - Wang, Chenmin
AU - Zheng, Lizhen
AU - Wang, Jiali
AU - Huang, Le
AU - Zu, Haiyue
AU - Yao, Zhi
AU - Mi, Jie
AU - Dai, Bingyang
AU - Li, Xu
AU - Yung, Patrick Shu hang
AU - Yuan, Guangyin
AU - Qin, Ling
N1 - Publisher Copyright:
© 2022
PY - 2024/1
Y1 - 2024/1
N2 - After reconstructing the anterior cruciate ligament (ACL), unsatisfactory bone tendon interface healing may often induce tunnel enlargement at the early healing stage. With good biological features and high formability, Magnesium-Zinc-Gadolinium (ZG21) wires are developed to bunch the tendon graft for matching the bone tunnel during transplantation. Microstructure, tensile strength, degradation, and cytotoxicity of ZG21 wire are evaluated. The rabbit model is used for assessing the biological effects of ZG21 wire by Micro-CT, histology, and mechanical test. The SEM/EDS, immunochemistry, and in vitro assessments are performed to investigate the underlying mechanism. Material tests demonstrate the high formability of ZG21 wire as surgical suture. Micro-CT shows ZG21 wire degradation accelerates tunnel bone formation, and histologically with earlier and more fibrocartilage regeneration at the healing interface. The mechanical test shows higher ultimate load in the ZG21 group. The SEM/EDS presents ZG21 wire degradation triggered calcium phosphate (Ca-P) deposition. IHC results demonstrate upregulation of Wnt3a, BMP2, and VEGF at the early phase and TGFβ3 and Type II collagen at the late phase of healing. In vitro tests also confirmed the Ca-P in the metal extract could elevate the expression of Wnt3a, β catenin, ocn and opn to stimulate osteogenesis. Ex vivo tests of clinical samples indicated suturing with ZG21 wire did not weaken the ultimate loading of human tendon tissue. In conclusion, the ZG21 wire is feasible for tendon graft bunching. Its degradation products accelerated intra-tunnel endochondral ossification at the early healing stage and therefore enhanced bone-tendon interface healing in ACL reconstruction.
AB - After reconstructing the anterior cruciate ligament (ACL), unsatisfactory bone tendon interface healing may often induce tunnel enlargement at the early healing stage. With good biological features and high formability, Magnesium-Zinc-Gadolinium (ZG21) wires are developed to bunch the tendon graft for matching the bone tunnel during transplantation. Microstructure, tensile strength, degradation, and cytotoxicity of ZG21 wire are evaluated. The rabbit model is used for assessing the biological effects of ZG21 wire by Micro-CT, histology, and mechanical test. The SEM/EDS, immunochemistry, and in vitro assessments are performed to investigate the underlying mechanism. Material tests demonstrate the high formability of ZG21 wire as surgical suture. Micro-CT shows ZG21 wire degradation accelerates tunnel bone formation, and histologically with earlier and more fibrocartilage regeneration at the healing interface. The mechanical test shows higher ultimate load in the ZG21 group. The SEM/EDS presents ZG21 wire degradation triggered calcium phosphate (Ca-P) deposition. IHC results demonstrate upregulation of Wnt3a, BMP2, and VEGF at the early phase and TGFβ3 and Type II collagen at the late phase of healing. In vitro tests also confirmed the Ca-P in the metal extract could elevate the expression of Wnt3a, β catenin, ocn and opn to stimulate osteogenesis. Ex vivo tests of clinical samples indicated suturing with ZG21 wire did not weaken the ultimate loading of human tendon tissue. In conclusion, the ZG21 wire is feasible for tendon graft bunching. Its degradation products accelerated intra-tunnel endochondral ossification at the early healing stage and therefore enhanced bone-tendon interface healing in ACL reconstruction.
KW - ACL reconstruction
KW - Biomaterials
KW - Endochondral ossification
KW - Magnesium alloy
KW - Magnesium wire
UR - http://www.scopus.com/inward/record.url?scp=85146973848&partnerID=8YFLogxK
U2 - 10.1016/j.jma.2022.12.006
DO - 10.1016/j.jma.2022.12.006
M3 - Journal article
AN - SCOPUS:85146973848
SN - 2213-9567
VL - 12
SP - 295
EP - 315
JO - Journal of Magnesium and Alloys
JF - Journal of Magnesium and Alloys
IS - 1
ER -