Experimental Study on Thermal Performance of Semi-transparent PV Window in Winter in Hong Kong

Meng Wang, Jinqing Peng, Nianping Li, Lin Lu, Hongxing Yang

Research output: Journal article publicationConference articleAcademic researchpeer-review

15 Citations (Scopus)

Abstract

Semi-transparent PV (STPV) windows can provide daylight illuminance and electricity generation simultaneously. The performance of semi-transparent PV in saving cooling energy has been proved in previous studies. This study presents the heating performance of STPV window in winter in Hong Kong. The passive heating effect of STPV was investigated experimentally. The results indicated that space heating is not needed for the room equipped with STPV in work time on sunny days. The SHGC and U-value of the STPV were also calculated. The average values of SHGC and U-value are 0.2 and 5.58 W/(m2K), respectively.
Original languageEnglish
Pages (from-to)864-868
Number of pages5
JournalEnergy Procedia
Volume105
DOIs
Publication statusPublished - 1 Jan 2017
Event8th International Conference on Applied Energy, ICAE 2016 - Beijing, China
Duration: 8 Oct 201611 Oct 2016

Keywords

  • Building integrated photovoltaic
  • Energy performance
  • EnergyPlus
  • PV/thermal
  • Semi-transparent PV

ASJC Scopus subject areas

  • Energy(all)

Fingerprint

Dive into the research topics of 'Experimental Study on Thermal Performance of Semi-transparent PV Window in Winter in Hong Kong'. Together they form a unique fingerprint.

Cite this