Effect of passive damping devices on wind-induced response of tall buildings

You Lin Xu, B. Samali, K. C S Kwok

Research output: Journal article publicationConference articleAcademic researchpeer-review

1 Citation (Scopus)

Abstract

An exploratory study is made of the possible application of Turned Liquid Column Dampers (TLCD) as an energy dissipating device to reduce the response of tall buildings and other structures subjected to wind loads. It is found that TLCD systems are capable of reducing the structural response with a relatively small mass and can achieve the same response reduction levels as those by traditional Tuned Mass Damper (TMD) systems with only half the mass. TLCD system offers several advantages including simplicity and retuning to natural period of the structure.
Original languageEnglish
Pages (from-to)127-132
Number of pages6
JournalNational Conference Publication - Institution of Engineers, Australia
Issue number90 pt 9
Publication statusPublished - 1 Dec 1990
Externally publishedYes
EventAustralian Vibration and Noise Conference 1990 - Melbourne, Australia
Duration: 18 Sep 199020 Sep 1990

ASJC Scopus subject areas

  • Engineering(all)

Cite this