TY - JOUR
T1 - Corrigendum
T2 - Modulations of static and dynamic functional connectivity among brain networks by electroacupuncture in post-stroke aphasia (Front. Neurol., (2022), 13, 956931, 10.3389/fneur.2022.956931)
AU - Xu, Minjie
AU - Gao, Ying
AU - Zhang, Hua
AU - Zhang, Binlong
AU - Lyu, Tianli
AU - Tan, Zhongjian
AU - Li, Changming
AU - Li, Xiaolin
AU - Huang, Xing
AU - Kong, Qiao
AU - Xiao, Juan
AU - Kranz, Georg S.
AU - Li, Shuren
AU - Chang, Jingling
N1 - Publisher Copyright:
© 2023 Xu, Gao, Zhang, Zhang, Lyu, Tan, Li, Li, Huang, Kong, Xiao, Kranz, Li and Chang.
PY - 2023/2/10
Y1 - 2023/2/10
N2 - In the published article, there was an inappropriate language error. The description of the EA technique omitted important details. A correction has been made to the section Stimuli and scanning procedure, Acupuncture procedures and needling sensation recording. The corrected paragraph is below. Both the PSA andHC groups received EA stimulation at the HT5 and GB39 acupoints during fMRI acquisition. Before the start of the scan, the participants positioned themselves on the fMRI scanner bed on their backs, and needles were placed at the GB39 and HT5 acupoints. According to the “Name and Location of Acupoints” (GB/T 12346-2006), two acupoints were located on both sides. HT5 was situated radially to the flexor carpi ulnaris tendon on the anteromedial side of the forearm, 33mm proximal to the palmar wrist crease, with insertion depths ranging from 10 to 30 mm. GB39 was needled at an insertion depth of 33 mm, 100mm above the external malleolus tip, on the anterior fibula border (Figure 2A). A professional acupuncturist performed acupuncture. All participants reported their experience (“Deqi”) with acupuncture stimulation. Deqi featured aching, pressure, heaviness, fullness, and numbness among other feelings (23–29). The acupuncturist used 0.40 × 40-mm sterile silver acupuncture needles (Guizhou, China) with the EA technique. Han’s acupoint nerve stimulator (model LH-202H) was situated outside the fMRI room, with one end of the acupoint wire linked to the acupuncture needle handle of the HT5 acupoint, and the other end connected to the acupuncture needle handle of the GB39 acupoint. The EA frequency was 2Hz, and the electric current was 2 mA. As previously mentioned, the stimulation waveform is the dilatational wave (23). The authors apologize for this error and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.
AB - In the published article, there was an inappropriate language error. The description of the EA technique omitted important details. A correction has been made to the section Stimuli and scanning procedure, Acupuncture procedures and needling sensation recording. The corrected paragraph is below. Both the PSA andHC groups received EA stimulation at the HT5 and GB39 acupoints during fMRI acquisition. Before the start of the scan, the participants positioned themselves on the fMRI scanner bed on their backs, and needles were placed at the GB39 and HT5 acupoints. According to the “Name and Location of Acupoints” (GB/T 12346-2006), two acupoints were located on both sides. HT5 was situated radially to the flexor carpi ulnaris tendon on the anteromedial side of the forearm, 33mm proximal to the palmar wrist crease, with insertion depths ranging from 10 to 30 mm. GB39 was needled at an insertion depth of 33 mm, 100mm above the external malleolus tip, on the anterior fibula border (Figure 2A). A professional acupuncturist performed acupuncture. All participants reported their experience (“Deqi”) with acupuncture stimulation. Deqi featured aching, pressure, heaviness, fullness, and numbness among other feelings (23–29). The acupuncturist used 0.40 × 40-mm sterile silver acupuncture needles (Guizhou, China) with the EA technique. Han’s acupoint nerve stimulator (model LH-202H) was situated outside the fMRI room, with one end of the acupoint wire linked to the acupuncture needle handle of the HT5 acupoint, and the other end connected to the acupuncture needle handle of the GB39 acupoint. The EA frequency was 2Hz, and the electric current was 2 mA. As previously mentioned, the stimulation waveform is the dilatational wave (23). The authors apologize for this error and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.
KW - brain networks
KW - electroacupuncture
KW - functional connectivity
KW - independent component analysis
KW - post stroke aphasia
KW - psychophysiological interaction analysis
UR - http://www.scopus.com/inward/record.url?scp=85148900340&partnerID=8YFLogxK
U2 - 10.3389/fneur.2023.1148220
DO - 10.3389/fneur.2023.1148220
M3 - Comment/debate/erratum
AN - SCOPUS:85148900340
SN - 1664-2295
VL - 14
JO - Frontiers in Neurology
JF - Frontiers in Neurology
M1 - 1148220
ER -