Corneal iron ring associated with orthokeratology lens wear

Hie Hua Wong, Wan Shan Chui, John Mountford, Sin Wan Cheung

Research output: Journal article publicationJournal articleAcademic researchpeer-review

31 Citations (Scopus)

Abstract

A healthy 27-year-old female with a history of daily wear soft contact lenses requested orthokeratology (ortho-k) treatment and was fitted with a pair of reverse geometry lenses. Two weeks later, a faint brown pigmented arc, with fuzzy margins, extending from four to eight o'clock at the inferior midperipheral part of the corneal surface was observed in both corneas. The patient was asymptomatic and happy with the results of the ortho-k treatment, and topographical maps showed a sharp and slightly decentered bull's eye pattern that indicated a clinically acceptable ortho-k effect for both eyes. The rings extended to a near-complete ring in both eyes and became denser and more significant as lens wear continued. The rings were similar in appearance to Fleischer's rings seen in keratoconic eyes and coincided with the margin of the bull's eye observed in the topographical maps. The patient continued to be asymptomatic with unaided visual acuity of 20/20+1(OD) and 20/25-1(OS). Apart from the presence of the iron rings bilaterally, the corneal integrity and topography were stable and clinically unremarkable; the patient was allowed to continue wearing the lenses with regular aftercare scheduled on a 3-month basis. Possible etiologies of the formation of iron rings are discussed.
Original languageEnglish
Pages (from-to)565-568
Number of pages4
JournalOptometry and Vision Science
Volume79
Issue number9
DOIs
Publication statusPublished - 1 Jan 2002

Keywords

  • Fleischer's ring
  • Iron ring
  • Orthokeratology

ASJC Scopus subject areas

  • Ophthalmology
  • Optometry

Fingerprint

Dive into the research topics of 'Corneal iron ring associated with orthokeratology lens wear'. Together they form a unique fingerprint.

Cite this