Abstract
The paper examines the contactless power conversion using the contactless power transformer. The primary and secondary sides of the transformer are separated by a large air-gap and hence the power transfer can be obtained without physical contact. The characteristics of the gapped transformer, the compensation methodology and PLL control for the converter are investigated. Experimental results using the contactless power converter are presented. A resonant converter method is used that can realized the high leakage imposed in the transformer.
Original language | English |
---|---|
Title of host publication | 7th IET International Conference on Advances in Power System Control, Operation and Management (APSCOM 2006) |
Edition | 523 CP |
DOIs | |
Publication status | Published - 1 Dec 2006 |
Event | 7th IET International Conference on Advances in Power System Control, Operation and Management, APSCOM 2006 - Hong Kong, Hong Kong Duration: 30 Oct 2006 → 2 Nov 2006 |
Conference
Conference | 7th IET International Conference on Advances in Power System Control, Operation and Management, APSCOM 2006 |
---|---|
Country/Territory | Hong Kong |
City | Hong Kong |
Period | 30/10/06 → 2/11/06 |
Keywords
- Air-gap
- Compensation
- Contactless
- Magnetics
- Power conversion
- Resonant converter
- Transformer
ASJC Scopus subject areas
- Electrical and Electronic Engineering