Contact force ratio: A new parameter to assess foot arch function

Kam Lun Leung, J. C.Y. Cheng, Ming Zhang, Y. Fan, X. Dong

Research output: Journal article publicationJournal articleAcademic researchpeer-review

11 Citations (Scopus)

Abstract

Static footprint parameters have been used to quantify arch height with conflicting results. This could be caused by the inherent inaccuracy and variations of the methodology used. Since the foot is a dynamic structure that undergoes changes during a step, it is more desirable to capture and analyse the dynamic footprint at an instant during the gait cycle that can most closely reflect the weight-bearing foot function. Forty (40) volunteer subjects were recruited for the reliability test of a new parameter, the Contact Force Ratio (CFR), derived from dynamic footprint. This is a measure of midfoot loading during gait. The mid-gait dynamic footprints were collected using a pressure sensing mat. Results of ICC tests showed that the CFR had good intratester (0.918) and intertester (0.909) reliability. The validity of the method was examined by correlating the parameter to the functional change in arch height, i.e. the Navicular Drop between the non-weight-bearing and weight-bearing conditions.
Original languageEnglish
Pages (from-to)167-174
Number of pages8
JournalProsthetics and Orthotics International
Volume28
Issue number2
DOIs
Publication statusPublished - 1 Jan 2004

ASJC Scopus subject areas

  • Health Professions (miscellaneous)
  • Rehabilitation

Fingerprint

Dive into the research topics of 'Contact force ratio: A new parameter to assess foot arch function'. Together they form a unique fingerprint.