TY - JOUR
T1 - Calibrating networks of low-cost air quality sensors
AU - Desouza, Priyanka
AU - Kahn, Ralph
AU - Stockman, Tehya
AU - Obermann, William
AU - Crawford, Ben
AU - Wang, An
AU - Crooks, James
AU - Li, Jing
AU - Kinney, Patrick
N1 - Funding Information:
Priyanka deSouza and Ben Crawford gratefully acknowledge a CU Denver Presidential Initiative grant that supported their work. The authors are grateful to the Love My Air team for setting up and maintaining the Love My Air network. The authors are also grateful to Carl Malings for the useful comments
Publisher Copyright:
Copyright © 2022 Priyanka deSouza et al.
PY - 2022/11/2
Y1 - 2022/11/2
N2 - Ambient fine particulate matter (PM2.5) pollution is a major health risk. Networks of low-cost sensors (LCS) are increasingly being used to understand local-scale air pollution variation. However, measurements from LCS have uncertainties that can act as a potential barrier to effective decision making. LCS data thus need adequate calibration to obtain good quality PM2.5 estimates. In order to develop calibration factors, one or more LCS are typically co-located with reference monitors for short or long periods of time. A calibration model is then developed that characterizes the relationships between the raw output of the LCS and measurements from the reference monitors. This calibration model is then typically transferred from the co-located sensors to other sensors in the network. Calibration models tend to be evaluated based on their performance only at co-location sites. It is often implicitly assumed that the conditions at the relatively sparse co-location sites are representative of the LCS network overall and that the calibration model developed is not overfitted to the co-location sites. Little work has explicitly evaluated how transferable calibration models developed at co-location sites are to the rest of an LCS network, even after appropriate cross-validation. Further, few studies have evaluated the sensitivity of key LCS use cases, such as hotspot detection, to the calibration model applied. Finally, there has been a dearth of research on how the duration of co-location (short-term or long-term) can impact these results. This paper attempts to fill these gaps using data from a dense network of LCS monitors in Denver deployed through the city's "Love My Air"program. It offers a series of transferability metrics for calibration models that can be used in other LCS networks and some suggestions as to which calibration model would be most useful for achieving different end goals.
AB - Ambient fine particulate matter (PM2.5) pollution is a major health risk. Networks of low-cost sensors (LCS) are increasingly being used to understand local-scale air pollution variation. However, measurements from LCS have uncertainties that can act as a potential barrier to effective decision making. LCS data thus need adequate calibration to obtain good quality PM2.5 estimates. In order to develop calibration factors, one or more LCS are typically co-located with reference monitors for short or long periods of time. A calibration model is then developed that characterizes the relationships between the raw output of the LCS and measurements from the reference monitors. This calibration model is then typically transferred from the co-located sensors to other sensors in the network. Calibration models tend to be evaluated based on their performance only at co-location sites. It is often implicitly assumed that the conditions at the relatively sparse co-location sites are representative of the LCS network overall and that the calibration model developed is not overfitted to the co-location sites. Little work has explicitly evaluated how transferable calibration models developed at co-location sites are to the rest of an LCS network, even after appropriate cross-validation. Further, few studies have evaluated the sensitivity of key LCS use cases, such as hotspot detection, to the calibration model applied. Finally, there has been a dearth of research on how the duration of co-location (short-term or long-term) can impact these results. This paper attempts to fill these gaps using data from a dense network of LCS monitors in Denver deployed through the city's "Love My Air"program. It offers a series of transferability metrics for calibration models that can be used in other LCS networks and some suggestions as to which calibration model would be most useful for achieving different end goals.
UR - http://www.scopus.com/inward/record.url?scp=85142607803&partnerID=8YFLogxK
U2 - 10.5194/amt-15-6309-2022
DO - 10.5194/amt-15-6309-2022
M3 - Journal article
AN - SCOPUS:85142607803
SN - 1867-1381
VL - 15
SP - 6309
EP - 6328
JO - Atmospheric Measurement Techniques
JF - Atmospheric Measurement Techniques
IS - 21
ER -