Biomechanical effects of cervical arthroplasty with U-shaped disc implant on segmental range of motion and loading of surrounding soft tissue

Zhong Jun Mo, Yan Bin Zhao, Li Zhen Wang, Yu Sun, Ming Zhang, Yu Bo Fan

Research output: Journal article publicationJournal articleAcademic researchpeer-review

62 Citations (Scopus)

Abstract

Purpose: Various design concepts have been adopted in cervical disc prostheses, including sliding articulation and standalone configuration. This study aimed to evaluate the biomechanical effects of the standalone U-shaped configuration on the cervical spine. Methods: Based on an intact finite element model of C3-C7, a standalone U-shaped implant (DCI) was installed at C5-C6 and compared with a sliding articulation design (Prodisc-C) and an anterior fusion system. The range of motion (ROM), adjacent intradiscal pressure (IDP) and capsular ligament strain were calculated under different spinal motions. Results: Compared to the intact configuration, the ROM at C5-C6 was reduced by 90 % after fusion, but increased by 70 % in the Prodisc-C model, while the maximum percentage change in the DCI model was 30 % decrease. At the adjacent segments, up to 32 % increase in ROM happened after fusion, while up to 34 % decrease occurred in Prodisc-C model and 17 % decrease in DCI model. The IDP increased by 11.6 % after fusion, but decreased by 5.6 and 6.3 % in the DCI and Prodisc-C model, respectively. The capsular ligament strain increased by 147 % in Prodisc-C and by 13 % in the DCI model. The DCI implant exhibited a high stress distribution. Conclusions: Spinal fusion resulted in compensatory increase of ROM at the adjacent sites, thereby elevating the IDP. Prodisc-C resulted in hyper-mobility at the operative site that led to an increase of ligament force and strain. The U-shaped implant could maintain the spinal kinematics and impose minimum influence on the adjacent soft tissues, despite the standalone configuration encountering the disadvantages of high stress distribution.
Original languageEnglish
Pages (from-to)613-621
Number of pages9
JournalEuropean Spine Journal
Volume23
Issue number3
DOIs
Publication statusPublished - 1 Jan 2014

Keywords

  • Cervical disc arthroplasty
  • Finite element method
  • Intradiscal pressure
  • Ligament strain
  • Range of motion
  • U-shaped implant

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Fingerprint

Dive into the research topics of 'Biomechanical effects of cervical arthroplasty with U-shaped disc implant on segmental range of motion and loading of surrounding soft tissue'. Together they form a unique fingerprint.

Cite this