Application of a cavity enhanced UV-LED spectrometer for measurements of atmospheric HONO and NO2 in Hong Kong

Tao Wu, Qiaozhi Zha, Weidong Chen, Zheng Xu, Tao Wang, Xingdao He

Research output: Chapter in book / Conference proceedingConference article published in proceeding or bookAcademic researchpeer-review

Abstract

A cavity enhanced UV-LED spectrometer was applied to measure ambient HONO and NO2 during field intercomparison campaign in HK. Detection limits of 0.3 ppbv for HONO and 1 ppbv for NO2 were achieved over 120s.

Original languageEnglish
Title of host publicationImaging and Applied Optics - Propagation Through and Characterization of Distributed Volume Turbulence, pcDVT 2014
PublisherOptical Society of America (OSA)
ISBN (Print)9781557523082, 9781557523082
Publication statusPublished - 1 Jan 2014
EventPropagation Through and Characterization of Distributed Volume Turbulence, pcDVT 2014 - Seattle, WA, United States
Duration: 13 Jul 201417 Jul 2014

Publication series

NameOptics InfoBase Conference Papers
ISSN (Electronic)2162-2701

Conference

ConferencePropagation Through and Characterization of Distributed Volume Turbulence, pcDVT 2014
Country/TerritoryUnited States
CitySeattle, WA
Period13/07/1417/07/14

ASJC Scopus subject areas

  • Instrumentation
  • Atomic and Molecular Physics, and Optics

Fingerprint

Dive into the research topics of 'Application of a cavity enhanced UV-LED spectrometer for measurements of atmospheric HONO and NO2 in Hong Kong'. Together they form a unique fingerprint.

Cite this