Air change rates in urban Chinese bedrooms

Jing Hou, Yuexia Sun, Qingyan Chen, Rongsai Cheng, Junjie Liu, Xiong Shen, Hongwei Tan, Haiguo Yin, Kailiang Huang, Yao Gao, Xilei Dai, Leiming Zhang, Bowen Liu, Jan Sundell

Research output: Journal article publicationJournal articleAcademic researchpeer-review

45 Citations (Scopus)

Abstract

The ventilation modalities in most Chinese residences are infiltration and opening windows. We measured infiltration rates and air change rates at night, with no attempt to change occupants' behaviors, of urban residences in five climate zones of China during four seasons. Using the CO2 decay method, we found the median infiltration rate for 294 residences to be 0.34 h−1. Using occupant-generated CO2 as tracer gas, we determined air change rates over the course of 1 year in 46 bedrooms at night from mass balance considerations. In 54% of the measurements, windows were closed, so ventilation was only by infiltration. Windows were mainly closed when the outdoor temperature was below 15°C and above 26°C. The median infiltration rates did not differ appreciably among seasons and climate zones and were always less than 0.45 h−1.

Original languageEnglish
Pages (from-to)828-839
Number of pages12
JournalIndoor Air
Volume29
Issue number5
DOIs
Publication statusPublished - 2019

Keywords

  • bedroom
  • carbon dioxide
  • infiltration rate
  • long-term measurements
  • residential building
  • windows opening behavior

ASJC Scopus subject areas

  • Environmental Engineering
  • Building and Construction
  • Public Health, Environmental and Occupational Health

Fingerprint

Dive into the research topics of 'Air change rates in urban Chinese bedrooms'. Together they form a unique fingerprint.

Cite this