Abstract
Hydroxyapatite (HA) coatings were fabricated by pulsed laser deposition (PLD) on commercially pure titanium which had been subjected to different types of pre-treatment. These include: (i) 60-grit SiC grinding, (ii) 320-grit SiC grinding, (iii) 1-μm diamond paste mirror-finishing, (iv) etching with Knoll solution, and (v) laser surface nitriding followed by selective etching. The HA coatings were pulsed laser deposited at different water-vapor pressures to determine the optimal processing conditions. The nitrided-etched specimen exhibits a three dimensional TiN dendritic network which promotes the adhesion between HA coating and titanium substrate. Among the specimens with different pre-treatments, the adhesion strength of HA is the highest for the nitrided-etched specimen, reaching about twice that for the mirror-finished specimen. Thin-film X-ray diffraction shows a high degree of crystallinity for the PLD deposited HA. According to energy-dispersive X-ray analysis, the Ca/P ratio of the deposited HA reaches an approximate value of 1.7, similar to that of the HA target. Scanning-electron microscopy reveals that the deposited HA is about 4 μm in thickness. Growth of apatite was rapidly induced on the HA coated specimens when immersed in Hanks' solution for 4 days, indicating that the PLD HA coating is highly bone bioactive. This could be partly due to the high wettability of the PLD HA surface.
Original language | English |
---|---|
Pages (from-to) | 5496-5501 |
Number of pages | 6 |
Journal | Thin Solid Films |
Volume | 517 |
Issue number | 18 |
DOIs | |
Publication status | Published - 31 Jul 2009 |
Keywords
- Adhesion
- Hydroxyapatite
- Nitriding
- Pulsed laser deposition
- Titanium
ASJC Scopus subject areas
- Electronic, Optical and Magnetic Materials
- Surfaces and Interfaces
- Surfaces, Coatings and Films
- Metals and Alloys
- Materials Chemistry