Abstract
The paper presents a two-dimension (2-D), direct-coupled circuit-field-motion, time-stepping, finite element analysis for a wound-rotor induction motor with time-stepping method. With the accurate torque computation, the start up transient of the induction motor is investigated. The field results both at no load and at rated load are obtained. The steady and transient performance of varied mechanical load is studied. The slip ring induction analysis results can be used for website design for green energy teaching.
Original language | English |
---|---|
Title of host publication | 2011 4th International Conference on Power Electronics Systems and Applications, PESA 2011 |
DOIs | |
Publication status | Published - 6 Sept 2011 |
Event | 2011 4th International Conference on Power Electronics Systems and Applications, PESA 2011 - Hong Kong, Hong Kong Duration: 8 Jun 2011 → 10 Jun 2011 |
Conference
Conference | 2011 4th International Conference on Power Electronics Systems and Applications, PESA 2011 |
---|---|
Country/Territory | Hong Kong |
City | Hong Kong |
Period | 8/06/11 → 10/06/11 |
Keywords
- finite element method
- slip ring induction motor
- startup transients
- Transient analysis
- transient behavior
ASJC Scopus subject areas
- Electrical and Electronic Engineering