Skip to main navigation Skip to search Skip to main content

基于双能锥束CT和深度学习的放疗在体剂量监测基准合成方法

Translated title of the contribution: A method to establish reference benchmarks for in vivo dose monitoring for radiotherapy based on dual-energy cone beam CT and deep learning
  • Huimin Hu
  • , Zhengkun Dong
  • , Shutong Yu
  • , Chen Lin
  • , Tian Li
  • , Yibao Zhang

Research output: Journal article publicationJournal articleAcademic researchpeer-review

Abstract

Objective To achieve the conversion from dual-energy cone-beam CT (DECBCT) at the kilovolt (KV) level to projections at the megavolt (MV) level using an improved CycleGAN network, in order to provide a potential reference benchmark and real-time monitoring of in vivo doses delivered by exit beams for the safe implementation of advanced techniques such as online adaptive radiotherapy. Methods Simulated patient data were generated using a 4D extended cardiac torso (XCAT) model, and projections were generated based on the geometric parameters of Varian′s onboard cone-beam CT. Furthermore, relative electron density (RED) images were derived from DECBCT images using an iterative dual-energy decomposition algorithm. The SE-CycleGAN and CycleGAN networks were trained to generate MV projection images using DECBCT projections and RED images, respectively. The performance of both methods was evaluated using metrics including structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and root mean square error (RMSE). Results SE-CycleGAN significantly outperformed CycleGAN in all evaluation metrics (Z = -23.92, -26.17, -25.54, -26.80, -11.54, -11.21, P<0.05), particularly in learning global information. Besides, although both methods generated satisfactory MV projections, training using DECBCT projections as input yielded better effects than training using RED images. For all the 3 636 sets of projections in the test set, the SE-CycleGAN and CycleGAN networks using DECBCT projections as input respectively yielded SSIMs of 0.997 7±0.000 7 and 0.997 1±0.001 6, PSNRs of 39.625 0±4.684 4 and 36.272 2±5.566 3, and RMSEs of 0.004 1±0.002 7 and 0.006 3±0.0043, respectively. In contrast, the SE-CycleGAN and CycleGAN networks using RED projections as input respectively yielded SSIMs of 0.996 8±0.001 0 and 0.996 2±0.001 5, PSNRs of 38.548 7±3.637 4 and 36.007 3±4.437 8, and RMSEs of 0.004 3±0.002 2 and 0.006 1±0.0037, respectively. Conclusions This study proposed a new method to establish reference benchmarks for in vivo dose monitoring based on DECBCT and deep learning technologies. This method is accurate and effective according to the preliminary validation using virtual simulation experiments.

Translated title of the contributionA method to establish reference benchmarks for in vivo dose monitoring for radiotherapy based on dual-energy cone beam CT and deep learning
Original languageChinese (Simplified)
Pages (from-to)129-136
Number of pages8
JournalChinese Journal of Radiological Medicine and Protection
Volume45
Issue number2
DOIs
Publication statusPublished - 25 Feb 2025

Keywords

  • Dual-energy cone-beam computed temography
  • Generative adversarial network (GAN)
  • In vivo dose monitoring
  • Online adaptive radiotherapy

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'A method to establish reference benchmarks for in vivo dose monitoring for radiotherapy based on dual-energy cone beam CT and deep learning'. Together they form a unique fingerprint.

Cite this